Electrical Systems [Charging System] [2004]

Related Products:

Applicable Models

Model group Year Model Serial
Yamaha International 2004 60hp All
Yamaha Outboard 2004 60hp All

Electrical Systems [Charging System] [2004]
LIT-18616-FT-60
Yamaha Marine

Charging system

(1) Lighting coil

(2) Rectifier Regulator

(3) Fuse

(4) Battery

B : Black

G : Green

R : Red

G/W : Green/white

Checking the lighting coil

  1. Measure the lighting coil output peak voltage. Replace the stator coil if below specification.

When checking the peak voltage do not touch any of the connections of the digital tester leads.

● Use the peak voltage adaptor with the digital circuit tester.
● When measuring the peak voltage, set the selector on the digital circuit tester to the DC voltage mode.

Digital multimeter: YU-34899-A

Digital circuit tester: 90890-03174

Peak voltage adaptor: YU-39991 / 90890-03172

Test harness (3 pins): YB-06770 / 90890-06770

Lighting coil output peak voltage: Green (G) - Green (G)

r/min Unloaded Unloaded Unloaded
r/min Cranking 1,500 3,500
DC V 11.9 42 127

Lighting coil resistance (use as reference): Green (G)-Green (G) 1.2-1.8 Ω at 20 °C (68 °F)

Checking the Rectifier Regulator

  1. Measure the Rectifier Regulator output peak voltage. If below specification, measure the lighting coil output peak voltage. Replace the Rectifier Regulator if the output peak voltage of the lighting coil is above specification.

When checking the peak voltage do not touch any of the connections of the digital tester leads.

● Use the peak voltage adaptor with the digital circuit tester.
● When measuring the peak voltage, set the selector on the digital circuit tester to the DC voltage mode.

Digital multimeter: YU-34899-A

Digital circuit tester: 90890-03174

Peak voltage adaptor: YU-39991 / 90890-03172

Test harness (4 pins): YB-06771 / 90890-06771

Rectifier Regulator output peak voltage: Red (R) - Black (B)

r/min Unloaded Unloaded
r/min 1,500 3,500
DC V 18.9 19.5

After starting the engine, disconnect the out put lead (red lead) of the Rectifier Regulator when measuring the output peak voltage.