Step 1: ENRICHMENT CONTROL SYSTEM

(1) Electrothermal valve coil
(2) Electrothermal ram
Y : Yellow
Y/B : Yellow/black
Step 2: POWER COIL

- Measure:
- Power coil (1) output peak voltage
Below specification ➝ Replace.
- Power coil (1) output peak voltage
| Power coil output peak voltage (Y/B-Y/B) | ||||
|---|---|---|---|---|
| r/min | Cranking Opened | Cranking Closed | 1500 | 3500 |
| V | 15 | 6 | 25 | 66 |
Step 3: ELECTROTHERMAL RAM

- Measure:
- Electrothermal ram projection length (a)
Out of specification ➝ Replace.
- Electrothermal ram projection length (a)
Measuring steps:
- Connect a 12-V battery to the electrothermal ram.
- Measure the length of the projection after applying power for five minutes.
Electrothermal ram projection maximum length (a) : 14 ∼ 15 mm (0.55 ∼ 0.59 in)