ENRICHMENT CONTROL SYSTEM

(1) Power coil
(2) Thermo heater plunger
(3) CDI unit
Y : Yellow
Y/B : Yellow/black
CHECKING THE BATTERY
CHECKING THE FUSE
CHECKING THE MAIN SWITCH
CHECKING THE POWER COIL OUTPUT PEAK VOLTAGE

Measure:
- Power coil output peak voltage
Below specification -> Replace the Power coil.

Peak voltage adaptor: YU-39991/90890-03169
CHECKING THE THERMO HEATER PLUNGER

- Measure:
- Thermo heater resistance
Out of specification -> Replace.
Thermo heater resistance
Yellow/Black (Y/B) -
Yellow/Black (Y/B)
18 Ω - 19 ft at 20 °C (68 °F)
- Measure:
- Thermo heater plunger projection length (a).
Out of specification -> Replace.
Measuring steps
(1) Connect a 12-V battery to the thermo heater plunger.
(2) Measure the length of the projection after applying power for five minutes.
Thermo heater plunger projection maximum length: maximum length: 14-15 mm (0.55 - 0.59 in)