ENRICHMENT CONTROL SYSTEM

(1) Electrothermal valve coil
(2) Electrothermal ram
Y : Yellow
Y/B : Yellow/Black
POWER BOBBIN
- Measure:
- Power bobbin (1) output peak voltage
Below specification -> Replace.
Power bobbin output peak voltage (Y/B-Y/B)
| r/min | Cranking | Cranking | 1500 | 1500 | 3500 | 3500 |
|---|---|---|---|---|---|---|
| r/min | t | * | t | * | t | * |
| V | 10 | 7 | 40 | 30 | 80 | 80 |
t : Circuit
- :Loaded

ELECTROTHERMAL RAM

- Measure:
- Electrothermal ram projection length (a)
Out of specification -> Replace.
Measuring steps:
Connect a 12 V battery to the electrothermal ram.
Measure the length of the projection after applying power for five minutes.
Electrothermal ram projection minimum length: 7 mm (0.3 in)