Step 1: Electrical system

- Align the protrusion (w) on the stator (4) with the slot (x) in the cover assembly (10), and then assemble the starter motor.

- Install the spring (y), pinion (11), pinion stopper (A), and clip (B).

- Install a new gasket (D), the spring (E), and the magnet switch (12).

TIP:
Before installing the starter motor to the power unit, make sure to check the starter motor operation. See “Checking the starter motor operation” (5-34).
Installing the starter motor
- Install the starter motor to the power unit. See “Installing the starter motor” (7-23).
Step 2: Command Link Multifunction Meter sensor
Checking the water pressure sensor (optional)
- Disconnect the water pressure sensor coupler (a).
- Turn the engine start switch to ON, and then measure the input voltage at the water pressure sensor coupler.

Water pressure sensor input voltage: Orange (O)-Black (B) 4.75-5.25 V
Remove the water pressure sensor, and then connect the pressure pump (1) and special service tool (2).
Apply positive pressure to the water pres sure sensor slowly, and then measure the output voltage.

Pressure pump (1): (commercially available)
Test harness (3 pins) (2): YB-06869
Water pressure sensor output voltage (reference data):
Blue/Black (UB)-Black (B)
2.5 V at 392.0 kPa (3.92 kgf/cm2, 56.8 psi)
4.5 V at 784.0 kPa (7.84 kgf/cm2, 113.7 psi)
Turn the engine start switch to OFF, and then disconnect the special service tool (2) and pressure pump (1).
Disconnect the engine ECM couplers (b) and (c).

- Check the wiring harness for continuity.

Wiring harness continuity:
Terminal 1-Terminal 16
Terminal 2-Terminal 31
Terminal 3-Terminal 46
- Install the water pressure sensor, and then connect the water pressure sensor coupler (a). See “Installing the water pressure sensor” (3-13).
- Connect the engine ECM coupler (b) and (c).
Checking the speed sensor (optional)
Disconnect the speed sensor coupler (a).
Turn the engine start switch to ON, and then measure the input voltage at the speed sensor coupler.

Speed sensor input voltage: Orange (O)-Black (B) 4.75-5.25 V
Remove the speed sensor, and then connect the pressure pump (1) and special service tool (2).
Apply positive pressure to the speed sensor slowly, and then measure the output voltage.

Pressure pump (1): (commercially available)
Test harness (3 pins) (2): YB-06869
Speed sensor output voltage (reference data):
Blue (L)-Black (B)
2.5 V at 392.0 kPa (3.92 kgf/cm2, 56.8 psi)
4.5 V at 784.0 kPa (7.84 kgf/cm2, 113.7 psi)
- Turn the engine start switch to OFF, and then disconnect the special service tool (2) and pressure pump (1).
- Disconnect the engine ECM couplers (b) and (c).

- Check the wiring harness for continuity.

Wiring harness continuity:
Terminal 1-Terminal 16
Terminal 2-Terminal 31
Terminal 3-Terminal 37
- Install the speed sensor, and then connect the speed sensor coupler (a). See “Installing the speed sensor” (3-14).
- Connect the engine ECM couplers (b) and (c).