CLEANING, INSPECTION AND REPAIR
CAUTION:
All measuring instruments should be handled with special care, or the correct measurement is impossible.On an instrument powered by dry batteries, they should be checked for voltage periodically and replaced, if necessary.
Low resistance measurement
When measuring the resistance of 10 Ω or less using the digital tester, the correct measurement cannot be obtained because of the tester's internal resistance.To obtain the correct value, subtract this internal resistance from the displayed measurement.s
Correct value = Displayed measurement-internal resistance
NOTE:
The internal resistance of the tester can be obtained by connecting both of its terminals.
SPARK-PLUG
- Refer to page 3-21 8-17
TESTING THE CDI SYSTEM

Using the 1-Y ignition-tester
High scale test:
1) Place switch in HIGH position. Plug the simulator into an electric outlet. 117VAC for ten seconds.
2) Remove the simulator from the outlet, and connect the "P" and "N" leads from the tester to the simulator as indicated on the bottom of the simulator.
3) Set the tester dial to 50, or below. Depress the button on the simulator. The indicator lamp on the tester should light.
Low scale test:
1) Place switch in LOW position.
2) Set tester dial to 50, or below.
3) Connect yellow lead to negative terminal of 12V battery. Connect red lead to positive terminal of 12V battery. Indicater lamp should light.
If lamp does not light, check tester batteries. If they are installed correctly and are good, check the clip leads for faulty connections. If no fault can be found, refer to the warranty statement for instructions for sending the tester back to Electro-Specialities, inc.

WARNING
Do not touch the plug pins on the simulator while depressing the button. An electrical shock will result.
Pre-test procedure:
1) If there is no spark, or the spark is weak, continue with the CDI test.
2) If a good spark is obtained, the problem is not with the CDI system, but possibly the spark-plug or other component is defective.

Connection of 1-Y ignition tester
Test#1
1) Disconnect the Black/Orange leads from the ignition coils.
2) Connect the tester's "P" and "N" clip leads as shown.
- (1) CDI unit
- (2) Test #1: CDI unit output Repeat test three times.

Tests #2 and #3
1) Disconnect the Brown lead and 4P connector.
2) Connect the tester's "P" and "N" clip leads as shown.
(1) Pulser coil
(2) Charge coil
(3) Test #2: Magneto charge coil output
(4) Test #3: Magneto pulser coils output
Repeat test three times.
The CDI system tests data (Tests. #1, #2 and #3)

The coil output varies greatly with cranking speed. Testing with the spark plugs out and good battery. Cranking the cold engine with the plugs in and a weak battery cannot be found proper readings.
WARNING
While taking spark check be carefull not to touch any connection of lead wires of the "spark volt checker".
PULSER COIL
Check the resistance of the pulser coils.

Pulser coil resistance : Black—White/Red : 168 ~ 252Ω at 20°C (68°F)
Black—White/Black : 168 ~ 252Ω at 20°C (68°F)
Black—White/Green : 168 - 252Ω at 20°C (68°F)
- (1) Black
- (2) White/Red
- (3) White/Black
- (4) White/Green
CHARGE COIL

Check the resistance of the charge coil.
Charge coil resistance : Brown — Blue 237 - 356Ω at 20°C (68°F)
LIGHTING COIL

Check the resistance of the lighting coil.
Lighting coil resistance : Green — Green
Standard (12V, 80W) : 0.53 -0.799 at 20°C (68°F)
NOTE:
When measuring the resistance of 10 Ω or less using the digital tester, the correct measurement cannot be obtained. Refer to "Lower resistance measurement".
IGNITION COIL
1) Inspect the high-tension cables and spark plug caps for damage and cracks.
2) Measure the resistance of the primary coil.
Ignition coil resistance : Black — Black/White
Primary coil : 0.18 ~ 0.24Ω at 20°C (68°F)

NOTE:
When measuring the resitance of 10 Ω or less using the digital tester, the correct measurement cannot be obtained. Refer to "Lower resistance measurement".

3) Measure the resistance of the secondary coil.
Ignition coil resistance : Black — Secondary lead
Secondary coil 2.7~3.7kfi at 20°C (68°F)
REPLACEMENT OF SPARK-PLUG CAP

1) Remove the spark-plug cap by pulling the cap, and remove the plug-cap spring from the high-tension cable.

2) Cut about 5 mm (0.2 in) off the end of the high-tension cable.
3) Referring to the diagram, strip about 5 mm (0.2 in) of the insulation off the end of the high-tension cable, and fit the plug cap spring.
4) Push the cap-spring into the plug-cap.
(1) Bend
(2) Contact
CDI UNIT

1) Measure the resistances of the CDI unit.
NOTE:
Digital tester can not be used for this inspection. Use analogue tester.
CDI resistance values will vary from meter to meter, especially with electronic digital meters. For some testers, polarity of leads is reversed.
W : White
B : Black
Br : Brown
L : Blue
W/R : White/Red
W/B : White/Black
W/G : White/Green
B/O : Black/Orange
B/W : Black/White
B/Y : Black/Yellow
P : Pink
O : Orange
O/G : Orange/Green
Y/R : Yellow/Red

NOTE:
The asterisk (*) indicates that the needle of the tester should swing towards "0" and then slowly swing back to indicate the specified value.
FUEL ENRICHMENT VALVE
40MH
40ER ✓
40PR ✓
40TR ✓
50ER ✓
50TH ✓
P50TR ✓

Measure the resistance of the fuel enrichment valve.
Valve resistance : Blue — Black 3.4 ~ 4.0 Ω at 20°C (68°F)
NOTE:
When measuring the resistance of 10 Ω or less using the digital tester, the correct measurement cannot be obtained. Refer to "Lower resistance measurement".
STARTER RELAY

40MH
40ER ✓
40PR
40TR ✓
50ER ✓
50TH ✓
P50TR ✓
1) Check for continuity between the terminals and the ends of the Black and Brown leads.
2) Test to ensure there is no continuity between terminals.
3) Check the relay operation.
- Connect a tester between the terminals of the starter relay. Connect the leads of the starter-relay to a 12-V battery:
Brown lead........................................... ( +)
Black lead.............................................(-)
Battery voltage : 12V
B : Black
Br: Brown
4) Check that there is continuity between the starter relay terminals. If the operation is not as specified, replace the starter relay.
POWER TRIM AND TILT RELAY
40MH
40ER
40PR
40TR ✓
50ER
50TH ✓
P50TR ✓
Refering power tilt relay.
POWER TILT RELAY

40MH
40ER
40PR ✓
40TR
50ER
50TH
P50TR
1) Check the relay for terminal looseness and for wiring rust and corrosion. Replace the relay if any of the three defects is found.

2) Connect the (+) terminal and (1) terminal, and the (+) terminal and (2)
terminal to the tester, and check that the resistance becomes °° in each case.
- (1) : Lg (Light green) terminal
- (2) : Sb (Sky blue) terminal
Sb : Sky blue
Lg : Light green
B : Black

3) Connect the (-) terminal and (1) terminal,
and the (-) terminal and (2) terminal to the tester, and check the continuity in each case.
- (1) : Lg (Light green) terminal
- (2) : Sb (Sky blue) terminal
4) Connect the light green terminal to the (+) terminal of the battery and the black terminal to the (-) terminal of the battery. Then connect the (+) terminal and (1) terminal to the tester and check the continuity.

Light green............................................(+)
Black..................................................(-)
Battery voltage : 12V
- (1) : Lg (Light green) terminal
5) Connect the sky-blue terminal to the (+) terminal of the battery and the black terminal to the (-) terminal of the battery. Then connect the (+) terminal and (2) terminal to the tester and check the continuity.

Sky blue................................................. (+)
Black.....................................................(-)
Battery voltage : 12V
- (2) : Sb (Sky blue) terminal
RECTIFIER

40MH
40ER ✓
40PR ✓
40TR ✓
50ER ✓
50TH ✓
P50TR ✓
1) Check the continuity of the rectifier.

If continuity is not as specified, replace the rectifier.
RECTIFIER REGULATOR (FOR CANADA)

40MH
40ER
40PR
40TR ✓
50ER
50TH
P50TR
1) Check the continuity of the rectifier regulator.

FUSE

40MH
40ER ✓
40PR ✓
40TR ✓
50ER ✓
50TH ✓
P50TR ✓
1) Referring to the diagram, check the continuity of the fuse. If the fuse is blown, replace with a fuse of correct rating.
Fuse rating : 10A
THERMO-SWITCH

1) Immerse the thermo-switch in water. While heating the water, check the continuity at the specified temperature.
2) While cooling the water, check the continuity at the specified temperature. If continuity is not as specified, replace the thermo-switch.
Thermo Switch Temperature:
Thermo Switch (Orange) :
(a) 45°C(113°F)
(b) 30°C (86°F)
Thermo Switch (Pink):
(a) 93°C (199°F)
(b) 83°C (181°F)

(1) Discontinuity
(2) Continuity
(3) Discontinuity
[a] Temperature
[b] Time
OIL-LEVEL SENSOR

1) Remove the circlip, and disassemble the oil level sensor.
- (1) Oil level sensor
- (2) Circlip (Bottom end)
- (3) Support tube

2) Referring to the illustrations and tables, check the continuity and resistance.
40MH ✓
40ER
40PR
40TR
50ER
50TH
P50TR
Marking : 6H4-21


40MH
40ER ✓
40PR ✓
40TR ✓
50ER ✓
50TH ✓
P50TR ✓
Marking : 6H4-12

3) Assemble as shown in the diagram.
40MH ✓
40ER
40PR
40TR
50ER ✓
50TH ✓
P50TR ✓
- (1) Plate (upper)
- (2) Float
- (3) Support-tube
- (4) Plate (lower)
- (5) Circlip
NOTE:
- Place the float with the magnet side upward.
- Assemble the support-tube with its hole side upward.
- Assemble the plate which has a hole at the bottom.

4) Assemble as shown in the diagram.
40MH
40ER ✓
40PR ✓
40TR ✓
50ER ✓
50TH ✓
P50TR ✓
- (1) Plate (upper)
- (2) Float
- (3) Support-tube
- (4) Plate (lower)
- (5) Circlip
NOTE:
- Place the float with the magnet side upward.
- Assemble the support-tube with its hole side upward.
- Assemble the plate which has a hole at the bottom.
CONTROL UNIT

40MH
40ER ✓
40PR ✓
40TR ✓
50ER ✓
50TH
P50TR
- Check the resistance. If any element is faulty, replace the unit.

Y/R : Yellow/Red
B : Black
G/Y : Green/Yellow
Br : Brown
L : Blue
R : Red
P : Pink
Y : Yellow
(1) Black
(2) Yellow
(3) Pink
(4) Green/Red
(5) Green
OIL-LEVEL WARNING LAMP (L.E.D.)

40MH ✓
40ER
40PR
40TR
50ER
50TH
P50TR
Test the Light Emitting Diode (L.E.D.) using a 1.5-V dry-cell battery.
If no light, replace the warning lamp.
Battery voltage: 1.5V
CAUTION:
Do not use a 12-V battery nor a larger capacity type, as this may damage the L.E.D. We recommend pen light battery.
OIL LEVEL WARNING LAMP
40MH
40ER ✓
40PR ✓
40TR ✓
50ER ✓
50TH
P50TR ✓
- Check the control unit as specified.
CAUTION:
Do not connect the battery between the pink and green/red leads. If connected, the lamp unit may be damaged.
- If any element is broken, replace the entire
unit.

a. Yellow lamp
- (1) Y : Connect to (+) of battery.
- (2) B : Connect to (-) of battery.
- (3) P : No connection is necessary.
- (4) G/R : No connection is necessary.
- (5) G : No connection is necessary
If the yellow lamp alone comes on with the connections above, the yellow lamp circuit is in good condition.

b. Red lamp
- (1) Y : Connect to (+) of battery.
- (2) B : Connect to (-) of battery.
- (3) P : No connection is necessary.
- (4) G/R : Connect to (-) of battery.
- (5) G : No connection is necessary.
If the red lamp alone comes on with the connections above, the red lamp circuit is in good condition.

c. Green lamp
- (1) Y : Connect to (+) of battery.
- (2) B : Connect to (-) of battery.
- (3) P : No connection is necessary.
- (4) G/R : No connection is necessary.
- (5) G : Connect to (-) of battery.
If the green lamp alone comes on with the connections above, the green lamp circuit is correct.

d. Resistance across the pink (3) and the green / red (4) terminals.
- (3) P : Connect to (-) of tester.
- (4) G/R : Connect to (+) of tester.
The tester needle should deflect with the connections above.
CAUTION:
Do not connect the battery between the pink and green/red leads. If connected, the lamp unit may be damaged.

- (3) P : Connect to (-) of tester.
- (4) G/R : Connect to (+) of tester.
If the tester needle will not deflect with the connections above, the circuit is in good condition.
WIRING HARNESS

40MH
40ER ✓
40PR ✓
40TR ✓
50ER ✓
50TH ✓
P50TR ✓
1) Check the continuity between the coupler side and each connector. Cores and pins of identical colours must be connected or a continuity test cannot be made.
2) If any of the cores is open-circuit, replace the wiring harness.
Lg : Light Green
P : Pink
Br : Brown
B : Black
L : Blue
Sb : Sky Blue
W : White
Y : Yellow
R : Red
G : Green
BATTERY
40MH
40ER ✓
40PR ✓
40TR ✓
50ER ✓
50TH ✓
P50TR ✓
•Refer to page 3-12.
ENGINE STOP SWITCH

1) Remove the lock-plate and check for continuity according to the chart below.
2) Install the lock-plate, and push the button to see that there is continuity. (Only 40MH)
40MH ✓
40ER
40PR
40TR
50ER
50TH ✓
P50TR
MAIN SWITCH

40MH
40ER
40PR
40TR
50ER
50TH ✓
P50TR
1) Check the continuity of the main switch. Replace if continuity is not as specified.
CHOKE SWITCH
40MH
40ER
40PR
40TR
50ER
50TH ✓
P50TR

1) Check the continuity of the choke switch. Replace if continuity is not as specified.

NEUTRAL SWITCH

40MH
40ER
40PR
40TR
50ER
50TH ✓
P50TR
1) Check the continuity of the neutral switch. Replace if continuity is not as specified.

POWER TRIM AND TILT SWITCH

40MH
40ER
40PR
40TR ✓
50ER
50TH ✓
P50TR ✓
1) To see that there is continuity, push the swith.


2) Check rubber seal.
Replace the seal if it has any damage.