Electrical System [Cleaning, Inspection And Repair] [1989]

Related Products:

Applicable Models

Model group Year Model Serial
Yamaha Outboard 1989 70hp All
Yamaha Outboard 1989 90hp All

Electrical System [Cleaning, Inspection And Repair] [1989]
LIT-18616-00-36
Yamaha Marine

CLEANING, INSPECTION AND REPAIR

M51000-0*

SPARKPLUG

  • Refer to page 3-24.

PULSER COILS
M51500-0*

(1) Black
(2) White/Red
(3) White/Black
(4) White/Green

1) Check the resistance of the pulser coils.

70 hp
Pulser coil resistance: Black—White/Red: 130Ω±10% at 20 deg.C (68 deg.F)
Black—White/Black: 130Ω±10% at 20 deg.C (68 deg.F)
Black—White/Green: 130Ω±10% at 20 deg.C (68 deg.F)

(1) White/Red
(2) White/Black
(3) White/Yellow
(4) White/Green

90 hp
Pulser coil resistance:
White/Black—White/Green: 380Ω±10% at 20 deg.C (68 deg.F)
White/Red—White/Yellow: 380Ω±10% at 20 deg.C (68 deg.F)

CHARGE COIL
M51800-0*
Check the resistance of the charge coil.

Charge coil resistance:
Brown—Black: 165Ω±10% at 20 deg.C (68 deg.F)

Charge coil resistance:
Brown—Blue: 850Ω±10% at 20 deg.C (68 deg.F)
Blue—Red: 120Ω±10% at 20 deg.C (68 deg.F)

LIGHTING COIL
M52000-0*
1) Check the resistance of the lighting coil.

70 hp
Lighting coil resistance:
Green—Green: Standard (12V, 80W): 0.45Ω±20% at 20 deg.C (68 deg.F).

90 hp
Lighting coil resistance:
Green—White: Standard (12V, 120W): 0.6Ω±10% at 20 deg.C (68 deg.F).

(1) Green

IGNITION COIL
M52502-0*
1) Inspect the high-tension cables and spark plug caps for damage and cracks.

2) Measure the resistance of the primary coil, Black—Black/White.

Ignition coil resistance:
Primary coil: 0.22Ω±20% at 20 deg.C (68 deg.F)

3) Measure the resistance of the secondary coil, Black—Secondary lead.

Ignition coil resistance:
Secondary coil: 4.8kΩ+10% at 20 deg.C (68 deg.F)

REPLACEMENT OF SPARK-PLUG CAP
M53000-0
1) Remove the spark-plug cap by pulling the cap, and remove the plug-cap spring from the high-tension cable.

2) Cut about 5 mm (0.2 in) off the end of the high-tension cable.

3) Referring to the diagram, strip about 5 mm (0.2 in) of the insulation off the end of the high-tension cable, and fit the plug cap spring.

4) Push the cap-spring into the plug-cap.

(1) Bend
(2) Contact

CDI UNIT
M53500-0*

1) Measure the resistances of the CDI unit.

70ET
W : White
B : Black
Br : Brown
W/R : White/Red
W/B : White/Black
W/G : White/Green
B/W : Black/White
P : Pink
Y/R : Yellow/Red
Gy : Grey

Stamped mark: TIA03-12A
Unit: kΩ

∞: No continuity

NOTE:
The asterisk (*) indicates that the needle of the tester should swing towards “O” and then slowly swing back to indicate the specified value.

90ET
W : White
B : Black
Br : Brown
W/R : White/Red
W/B : White/Black
W/G : White/Green
B/W : Black/White
P : Pink
Y/R : Yellow/Red
Gy : Grey

Stamped mark: TIA03-15
unit: kΩ

∞: No continuity

NOTE:
The asterisk (*) indicates that the needle of the tester should swing towards “0” and then slowly swing back to indicate the specified value.

TESTING THE CDI SYSTEM

M54002-1
Using the 1-Y ignition-tester

  1. High scale test:
    1) Place switch in HIGH position. Plug the simulator into an electric outlet. 177VAC for ten seconds.
    2) Remove the simulator from the outlet, and connect the “P” and “N” leads from the tester to the simulator as indicated on the bottom of the simulator.
    3) Set the tester dial to 50, or below. Depress the button on the simulator. The indicator lamp on the tester should light.

  1. Low scale test:

1) Place switch in LOW position.
2) Set tester dial to 50, or below.
3) Connect yellow lead to negative terminal of 12V battery. Connect red lead to positive terminal of 12V battery. Indicater lamp should light.

If lamp does not light, check tester batterys. If they are installed correctly and are good, check the clip leads for faulty connections. If no fault can be found, refer to the warranty statement for instructions for sending the tester back to Electro-Specialities, inc.

WARNING:
Do not touch the plug pins on the simulator while depressing the button. A mild shock will result.

  1. Pre-test procedure:
    1) If there is no spark, or the spark is weak, continue with the CDI test.
    2) If a good spark is obtained, the problem is not with the CDI system, but possibly the spark-plug or other component is defective.

  2. Connection of 1-Y ignition tester
    Test #1
    1) Disconnect the Black/White leads from the ignition coils.
    2) Connect the tester’s “P” and “N” clip leads as shown.

NOTE:
In this test, connect the load coil, provided along with the tester, between the CDI unit output and the ground.

Tests #2 and #3

1) Disconnect the Brown lead and 4P connector.
2) Connect the tester’s “P” and “N” clip leads as shown.

  1. Testing the CDI system
    1) Place the tester range switch to the position indicated on the chart.
    2) Set the dial to the setting shown on the chart.

3) Crank the engine; if the light comes on, the component is good proceed to the next test. If the light does not come on, replace the component.
4) When the indicator lamp lights in each test, reset the indicator circuit by depressing the RESET button for the next test.

TEST LEAD CONNECTIONS TEST LEAD CONNECTIONS
"P" "N"
TEST
SEQUENCE
DIAL
SETTING
RANGE
SWITHC
Test #1
CDI output
Black/White Ground 60 H
Use load coil
Test #2
Charge coil
Brown Black 75 H
Test #3a
Pulser #1
White/Red Black 40 L
Test #3b
Pulser #2
White/Green Black 40 L
Test #3c
Pulser #3
White/Black Black 40 L

NOTE:
The CDI unit will not turn on the tester light if a pulser or charge coil is defective; test these coils before replacing the CDI unit.

CHOKE SOLENOID
M54500-0*
Measure the resistance of the choke solenoid,
Blue—Black.

Choke solenoid resistance: 3.7±0.3Ω at 20 deg.C (68 deg.F)

STARTER RELAY
M55000-0
1) Check for continuity between the terminals and the ends of the Black and Brown leads.
2) Test to ensure there is no continuity between terminals.
3) Check the relay operation.

  1. Connect a tester between the terminals of the starter relay. Connect the leads of the starter-relay to a 12-V battery:

Brown lead ..............(+)
Black lead ..............(-)
Battery voltage: 12V

B : Black
Br: Brown

4) Check that there is continuity between the starter relay terminals. If the operation is not as specified, replace the starter relay.

POWER TRIM AND TILT RELAY (90 hp)
Check the power trim and tilt relay in the same manner as that of the starter relay.
This is the same parts as starter relay (70 hp).

POWER TRIM & TILT SWITCH
M56100-0
Check the power trim and tilt switch as specified.

Up operation
Red—Sky blue
Released ......................Discontinuity
Pushed ........................ Continuity

Down operation
Red-Light green

Released ...........................Discontinuity
Pushed .............................. Continuity

RECTIFIER
M56501-0
1) Check the continuity of the rectifier.

70 hp

∞: No continuity

90 hp

∞: No continuity

If continuity is not as specified, replace the rectifier.

NOTE:

  1. Never connect the rectifier directly to the battery to check continuity.
  2. When testing, disconnect the battery terminals.
  3. When resistance is mesured at less than 1009, it can be said that there is continuity.

FUSE
M57001-0*
1) Referring to the diagram, check the continuity of the fuse. If the fuse is blown, replace with a fuse of correct rating.

Fuse rating:
70 hp........................ 10A
90 hp........................ 20A

THERMO-SWITCH
M57300-0

  1. Immerse the thermo-switch in water. While heating the water, check the continuity at the specified temperature.
  2. While cooling the water, check the continuity at the specified temperature.
    If continuity is not as specified, replace the thermo-switch.

(1) Discontinuity
(2) Continuity
(3) Discontinuity

(A) Temperature
(B) Time

OIL INJECTION SYSTEM
M57500-0
(1) Oil level sensor
(2) Digital meter (Oil level warning lamps/control unit)
(3) Lead wire
(4) Lead wire
(5) Lead wire assembly

OIL-LEVEL SENSOR
M58000-0
1) Remove the circlip, and disassemble the oil level sensor.

(1) Oil level sensor
(2) Circlip (Bottom end)
(3) Support tube

2) Referring to the illustrations and tables, check the continuity and resistance.

70 hp
Marking: 6H3-12

Unit: Ω

*“∞” indicates that the pointer deflects once and
returns to “∞”.

90 hp
Marking: 6H1-11
Unit: Ω

*“∞” indicates that the pointer deflects once and returns to “∞”.

3) Assemble as shown in the diagram.

(1) Plate (upper) and circlip
(2) Float
(3) Support-tube
(4) Plate (lower)
(5) Circlip

NOTE:

  1. Place the float with the magnet side upward.
  2. Assemble the support-tube with its hole side upward.
  3. Assemble the plate which has a hole at the bottom.

CONTROL UNIT
M57900-0

  1. Check the resistance. If any element is faulty, replace the entire unit.

TESTER SELECTER x lkΩ
Unit: kΩ

*The black terminal (1) is grounded to the radiating plate (6).

∞: No continuity
G/R :Green/Red
Y/R :Yellow/Red
G/Y :Green/Yellow
Y :Yellow
Br :Brown
L :Blue
R :Red
P :Pink
B :Black
G :Green

(1) Black
(2) Yellow
(3) Pink
(4) Green/Red
(5) Green

WIRING HARNESS
M58300-0
1) Check the continuity between the coupler side and each connector. Cores and pins of identical colours must be connected or a continuity test cannot be made.
2) If any of the cores is open-circuit, replace the wiring harness.

Lg : Light Green
P : Pink
Br : Brown
B : Black
L : Blue
Sb : Sky Blue
W : White
Y : Yellow
R : Red
G : Green

BRACKET
M58800-0
1) Inspect the bracket and replace it if its cracked.

BATTERY
M58900-0*

  • Refer to page 3-10.

INSTALLATION

M61002-0*
FLYWHEEL MAGNETO
1) Install the magneto base on to the retainer-plate.
2) Install the flywheel rotor on the crankshaft so that the woodruff key fits in the keyways in the crankshaft and flywheel rotor.
3) Lock the flywheel rotor with the washer and nut to the specified torque.

Flywheel nut: 160 Nm (16 m•kg, 115 ft•lb)

4) Install the flywheel cover.

Share on social:

Related Products