Electrical System [Checking The Electrical Component] [2017]

Related Products:
Electrical System [Checking The Electrical Component] [2017]
LIT-18616-03-36
Yamaha Marine

Using the YDIS

When checking the ETV, TPS, OCV, ignition spark, APS, high-pressure fuel pump, fuel injector, or each sensor, use the YDIS.

When deleting the diagnosis record in the YDIS, make sure to check the time that the trouble codes were detected.

When checking the input voltage of a component, the coupler or connector must be dis connected. As a result, the engine ECM determines that the component is disconnected and a trouble code is detected. Therefore, make sure to delete the diagnosis record after checking the input voltage.

YDIS (CD-ROM, Ver. 1.33): LIT-YDIS1-33-00
YDIS USB adapter and cable: 60V-WS850-00

TIP:

  • Before checking the electrical components, make sure that the battery is fully charged.
  • Install the proprietary YDIS software on the CD-ROM onto the computer. Always use the exclusive communication cable to connect the engine ECM to the computer. For a description of the communication cable and CD-ROM to be used, see “YDIS” (4-1). Also, make sure to check the CD-ROM ver sion before using it.
  • To connect and operate the YDIS, see the YDIS (Ver. 1.33 or later) Instruction Manual.

Measuring the peak voltage

WARNING
When measuring the peak voltage, do not touch any of the connections of the digital tester probes.

NOTICE
When measuring the peak voltage between the terminals of a electrical component using the digital tester, make sure that the leads do not contact any metal parts. Otherwise, the electrical component may short-circuit and be damaged.

To check the electrical components or measure the peak voltage, use the special service tools. A malfunctioning electrical component can be checked easily by measuring the peak voltage. The specified engine speed when measuring the peak voltage is affected by many factors, such as fouled spark plugs or a weak battery. If one of these factors is present, the peak voltage cannot be measured properly.

Digital multimeter: YU-34899-A
Peak volt adapter: YU-39991

TIP:

  • Before measuring the peak voltage, check all of the wiring harnesses for corrosion. Also, make sure that the wiring harnesses are connected properly and that the battery is fully charged.
  • Use the peak volt adapter with the recommended digital multimeter.
  • Connect the positive pin of the peak volt adapter to the positive terminal of the digital multimeter, and the negative pin to the negative terminal.
  • When measuring the peak voltage, set the digital multimeter to the DC voltage mode.

Using the digital tester

The electrical technical data apply to the measurements taken using the Yamaha-recommended tester.

The resistance values shown are the values taken before the engine is started. The actual resistance may vary depending on the environmental conditions and ambient temperature.

The input voltage changes depending on the battery voltage.

If the tester probe cannot be inserted into the coupler, prepare a test lead suitable for the measurement.

Digital multimeter: YU-34899-A Test lead:

  • Terminal, male (1): (commercially available)
    Terminal, female (2): (commercially available)

Engine control system and component

Checking the main relay

  1. Remove the intake manifold (STBD). See “Removing the intake manifold” (6-17).

  2. Remove the fuse cover and relay cover, and then remove the main relay (1). NOTICE: Be careful not to damage the relay.

  1. Connect the positive battery lead to the terminal (a), connect the negative battery lead to the terminal (b), and then check for continuity between the terminals (c) and (d). Replace the relay if there is no continuity. NOTICE: Do not reverse the battery leads.

  1. Measure the input voltage between the terminal (e) and ground, and the terminal (f) and ground.

Main relay input voltage:

  • Terminal (e)-Ground
  • Terminal (f)-Ground

12.0 V (battery voltage)