GENERAL SPECIFICATIONS


MAINTENANCE SPECIFICATIONS
- Engine


*1: Port #168
Starboard #160

- Electrical
1) Power unit


NOTE:
- The resistance measured in this test should be used as reference.
- Use the Pocket Tester (YU-3112) for this test. If any other tester is used, the measurements will be unreliable.
- When checking the C.D.I. unit, be sure to set the ohmmeter to the Ωx1000 range.

NOTE:
- Use the Pocket Tester (YU-3112) for this test.
If any other tester is used, the measurements will the unreliable.
- When checking the Control unit be sure to set the ohmmeter to the Ωx1000 range.
- The resistance measured in this test should be used as reference.

- Oil injection system
1) Basic specifications

2) Control unit ass'y

Measuring resistance

NOTE:
1. The resistance measured in this test should be used as reference.
2. Use the Pocket Tester (YU-3112) for this test. If any other tester is used, the measurements will be unreliable.
3. When checking the control unit, be sure to set the ohmmeter to the Qx 1k range.
4. Make the measurement with the unit placed in a horizontal position.

(a) *1 Tilt switch "ON"
(b) Tilt control unit
(c) *2 Emergency switch "ON"
(d) Hold emergency switch knob on "ON"
3) Oil injection pump

Conditions and points of safety:
Keep the engine speed at 1,500 r/min without fluctuations while measuring.
Open oil injection pump lever completely (more than 50° turn).
Oil temperature: 10°C (50°F)~30°C (86°F)
Each port most emmit a minumum of 0.1cm3 (0.0035 Imp oz, 0.0034 US oz) in three minutes. Use the proper graduated cylinder to measure this output. Be sure there is no oil in the cylinder before you use it. To avoid mistakes lengthen the time and take three minutes out of it to find the results.
Be sure to bleed the pump properly and that there is not air in the hose after it is replaced.
The table above is of data gathered from tests performed with YAMAHA OIL and may differ from tests with another brand.
Results may differ from port to port, also remember that tests must t be performed on each cylinder separately.


(1) Hose
(2) Don't let any oil drip onto the side of the cylinder.
(3) Cylinder
4) Remote oil tank
(1) Oil feed pump motor
| Motor type | DC Ferrite motor | Pumptype | Gear pump |
|---|---|---|---|
| Motor rating | 60 seconds | Compression | 1.5 kg/cm2 |
| Voltage | 120V | Capacity | 200±70 cm3/min |
| Amperage | below 1.5A |
(2) Level guage

B/R: Black/Red
B: Black
L: Blue

Switch (SW1, SW2 & SW3) "ON" x 100f2 range ± 20%

*∞ : The pointer deflects once and returns to ∞.
— : No check is necessary.

Lamps rating (Bulb) 12V 3.4W
NOTE:
In the case that the warning lamp system does not work, no lamp will come on. If this happens, it will be necessary to check the oil level immediately.
5) Engine oil tank
(1) Oil level gauge
Switch (SW1, SW2 & SW3) “OFF” x 100Ω range

*∞ : The pointer deflects once and returns to ∞.
6) Oil level warning lamps
| 1.Green | More than 1.5 €(0.33 Imp gal, 0.4 US gal) in remote oil tank. More than 500 cm3 (17.6 Imp oz, 16.9 US oz) in engine oil tank. |
No need for oil refill, operation possible. |
|---|---|---|
| 2.Yellow | Less than 1.5 £ (0.33 Imp gal, 0.4 US gal) in remote oil tank | No oil reserve. Refill remote oil tank as soon as possible. |
| 3.Red | Less than 1.5 £ (0.33 Imp gal, 0.4 US gal) in remote oil tank. Less than 300 cm3 (10.5 Imp oz, (10.1 USoz) in engine oil tank. | Danger, must refill remote oil tank. Almost no oil left. Stop engine and refill with oil. |
| 4.Green and Red | More than 1.5 £ (0.33 Imp gal, 0.4 US gal) in remote oil tank. Put less than 300 cm3 (10.5 Imp oz, 10.1 USoz) in engine oil tank. | Danger, must refill engine oil tank. Check oil feed pump and related |
| parts. For some reason oil in remote oil tank is not reaching remote oil tank. |
2. Power trim and tilt Power trim and tilt motor
| Rating | sec. | 60 |
|---|---|---|
| Output | kW | 0.4 |
| Carbon brush length (Water limit) |
mm (in) mm (in) |
11.5 (0.45) 7.5 (0.3) |
3. Remote control
Main switch
B: Black
P: Pink
Y: Yellow
W: White
G: Green
Br: Brown
R: Red
a) Main switch is OFF

White - Black Continuity
b) Main switch is ON
Red - Yellow Continuity
c) Main switch is i START position
Red - Yellow Continuity
Red - Brown Continuity
There is no continuity when lead wires are connected in different ways.

Choke switch

a) Choke switch OFF
Blue - Yellow Discontinuity
b) Choke switch ON
Blue - Yellow Continuity
Emergency stop switch

a) Lock plate installed
White - Black Continuity
Neutral switch

a) Released
Brown - Brown Discontinuity
b) Pushed
Brown - Brown Continuity
Power trim and tilt switch

UP
a) Released
Skyblue - Red Discontinuity
b) Pushed
Skyblue - Red Continuity

DOWN (DN)
a) Released
Red - Light green Discontinuity
b) Pushed
Red - Light green Continuity
- Lower casing unit

- Power trim and tilt